Fault Level Study and Earthing Calculator

Follows the fault from the utility source all the way to the final board, and gives you the short-circuit current at every point on the way. It then sizes the earthing for that same fault current. Two studies that are normally done separately, from one model of the installation.

The fault path, not just a table of numbers

Most submitted fault level studies give a list of buses and a current against each, with no indication of how the current got there. A reviewer cannot check that. This application models the path itself — every component with impedance, in order — and reports a fault point after each one.

A typical path runs from the utility source, down the HT cable, through the ring main unit, into the transformer, along the busduct, into the LT panel and on to the final board. At each fault point you get:

Because the path is explicit, the drop from one fault point to the next is explainable. That is the difference between a study a reviewer accepts and one that comes back with comments.

Components you can model

Source

Utility fault level in MVA at the incoming voltage, or a generator source, as the starting impedance for the whole study.

Cables and busduct

HT and LT cable runs by size, length and number of runs, and busduct by rating and length — each adding its own impedance to the running total.

Transformers and switchgear

Transformer rating and impedance, ring main units, and the LT panel incomer, so the step down in fault current across each is shown rather than assumed.

Earthing design, in the same tool

The earthing module takes the fault current the study has just calculated, rather than a figure typed in from somewhere else, and designs the system to IS 3043 against it.

Earthing sized against a guessed fault current is one of the commonest findings in a design review. Taking the figure straight from the fault study removes that argument.

Standards and reporting

The reports are written to be submitted. A reviewing engineer can follow the working rather than take a number on trust, which is usually what they are asking for when a study is returned.

It feeds the breaker study

The fault currents calculated here are what the Breaker Release Curve and Settings application needs in order to check discrimination at a real fault level rather than a nominal one. The two are designed to be used together, which is why one licence key covers both.

Use the Fault Level Study and Earthing Calculator on your next job